Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NSD15-48D12 is the 12V -12V output model of this series: rated current 0.62A 0.62A, rated power 14.88W, typical efficiency 84%.
Features
- Wide 4:1 DC input range
- Protections: Short circuit / Overload / Over voltage
- 1500VDC I/O isolation
- Built-in EMI filter
- Cooling by free air convection
- Output voltage trimming function
- Built-in remote ON-OFF control
- 100% full load burn-in test
- Lost cost
- High reliability
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V -12V
- RATED CURRENT
- 0.62A 0.62A
- CURRENT RANGE
- 0.03 ~ 0.62A 0.03 ~ 0.62A
- RATED POWER
- 14.88W
- CAPACITIVE LOAD (max.)
- ±1000uF
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p(25% ~ 100% load)
- VOLTAGE TOLERANCENote.3
- ±2.5%
- LINE REGULATION
- ±1.0% at 10% ~ 100% load
- LOAD REGULATION
- ±1.0%
- TRIM OUTPUT (Typ.)
- ±5.0%
- SETUP TIME
- 100ms/RATED DC INPUT at full Load
INPUT
- RATED DC INPUT
- 48VDC
- VOLTAGE RANGENote.6
- 18 ~ 72VDC
- EFFICIENCY (Typ.)
- 84%
- DC CURRENT
- 0.4A/48VDC
- SHUTDOWN IDLE CURRENT
- 20mA
PROTECTION
- OVERLOAD
- Above 105% rated output power Protection type : Over power limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE(CLAMP)
- 13.8 ~ 18V -13.8 ~ -18V
- SHORT CIRCUITNote.4
- Recovers automatically after fault condition is removed
FUNCTION
- ON/OFF CONTROL
- Logic "1" or open circuit : ON Logic "0" or short to PIN2 : OFF
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃
- WORKING HUMIDITY
- 0% ~ 95% RH max.
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 0 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~50℃)
SAFETY & EMC (Note 5)
- SAFETY STANDARDS
- UL62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
- ISOLATION VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,6,8; BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 9469.6K hrs min. Telcordia SR-332 (Bellcore) ; 1673.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*38.1*9.82mm (2"*1.5"*0.387") (L*W*H)
- PACKING
- 0.03Kg; 180pcs/6.4Kg/0.94CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 12, 48VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Short circuit no more than 60 seconds.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. Derating to 80% load is needed for NSD15-48D series at 18Vdc input voltage. Full output wattage can be acquired when the input voltage is higher than 20Vdc.
- 7. EMC filter suggestion:
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the NSD15-48D12 for equipment that needs a ±12V rail from a higher-voltage input source?
Yes, if the equipment is designed for constant-voltage ±12V output and the load stays within 14.88W. This model accepts 18~72V input, so it is intended for higher-input systems than the 9.4~36V versions.
Is this DC-DC converter suitable for industrial analog or signal-conditioning circuits that require ±12V?
It can fit industrial analog or signal-conditioning electronics that require a constant ±12V output and stay within the 14.88W rating. The 18~72V input range is relevant where the available source voltage is already in that higher band.
Can the NSD15-48D12 be used in automation systems with an 18~72V input bus?
Yes, if the automation system needs a constant ±12V output and the connected load remains within 14.88W. Full output is available above 20V input; at 18V input the load must be derated to 80%.
Is the NSD15-48D12 rated for outdoor use or only controlled environments?
The specified operating temperature is -25°C to +70°C. No IP rating is listed, so the specifications do not confirm suitability for direct outdoor exposure or wet locations.
How does the NSD15-48D12 compare with other NSD15 models?
The NSD15-D family includes 9.4~36V input and 18~72V input models, with outputs of ±5V at 1.5A and 15W, ±12V at 0.62A and 14.88W, and ±15V at 0.5A and 15W. The NSD15-48D12 is the 18~72V input, ±12V, 14.88W version. Compared with the 9.4~36V NSD15-12D12, its main difference is the higher specified input range.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NSD15 Models
13 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.