Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well PHP-3500-24 power supply 3500W 24V 145A
Overview
PHP-3500-24 is the 24V output model of this series: rated current 145A, rated power 3480W, typical efficiency 95%.
PHP-3500 series is a 3500W single-output slim type power supply with 60mm of low profile design. Adopting the full range 90~264Vac input, the entire series provides an output voltage line of 24V and 48V. In addition to the high efficiency up to 96%, that the whole series operates from -30℃ ~ +70℃ under air convection without fan. PHP-3500 has the complete protection functions and 2G anti-vibration capability; it complies with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1, and design refers to BS EN/EN61558-1 and BS EN/EN60335-1. PHP-3500 series serves as a high performance power supply solution for various industrial applications.
Features
- 90 ~ 264Vac input with PFC
- Slim and Low profile (60mm)
- Fanless design, cooling by water conduction
- Built-in PMBus or CANBus protocol
- Output voltage and constant current level programmable
- Protections: Short circuit / Overload / Over voltage / Over temperature
- -30 ~ +70℃ working temperature
- Built-in remote ON-OFF control
- DC OK active signal
- Optional cold plate for quick implementation
- OVCⅢ Operating altitude up to 3000 meter (Note.9)
- LED indicator for power on
- High efficiency up to 96%
- Active current sharing up to 14000W (3+1)
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 145A
- RATED POWER
- 3480W
- RIPPLE & NOISE (max.)Note.2
- 300mVp-p
- VOLTAGE ADJ. RANGE
- By built-in potentiometer, SVR
- VOLTAGE ADJ. RANGE
- 24~28.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.4
- 1500ms, 60ms/230Vac 1500ms, 60ms/115Vac at full load
- HOLD UP TIME (Typ.)Note.4
- 16ms/230Vac at 75% load 10ms/230Vac at full load ; 16ms/115Vac at 75% load 10ms/115Vac at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264Vac 127 ~ 370Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)Note.4
- PF≥0.95/230Vac PF≥0.99/115Vac at full load
- EFFICIENCY (Typ.)Note.10
- 95%
- AC CURRENT (Typ.)
- 20A/115Vac 20A/230Vac
- INRUSH CURRENT (Typ.)
- Cold start 30A/115Vac 80A/230Vac
- LEAKAGE CURRENT
- 2mA / 240Vac
PROTECTION
- OVERLOAD
- 105 ~ 115% rated current Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover
- OVER VOLTAGE
- 30 ~ 36V Protection type :Shut down O/P voltage,re-power on to recover
- OVER TEMPERATURE
- Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)Note.5,6
- Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage. Please refer to the Function Manual.
- OUTPUT CURRENT PROGRAMMABLE(PC)Note.6
- Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
- REMOTE ON/OFF CONTROL
- Power ON : Short circuit Power OFF : Open circuit
- AUXILIARY POWER
- 12V@0.5A tolerance±10%, ripple 150mVp-p
- DC-OK SIGNAL
- The TTL signal out, PSU turn on = -0.5 ~ 0.5Vdc ; PSU turn off = 3.5 ~ 5.5Vdc. Please refer to the Function Manual.
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃Baseplate temperature (Refer to “Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
- OVER VOLTAGE CATEGORY
- Ⅱ; According to EN61558; altitude up to 5000 meters.
SAFETY & EMC (Note.8)
- SAFETY STANDARDS
- UL62368-1, CAN/CSA C22.2 No. 62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved ; design refers to BS EN/EN61558-1, BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3KVac I/P-FG:2KVac O/P-FG:1.25KVac
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500Vdc/25℃/ 70%RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class A Radiated BS EN/EN55032 (CISPR32) Class A Harmonic Current BS EN/EN61000-3-12 Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 544.8K hrs min. Telcordia SR-332 (Bellcore) ; 56.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- Forced-air cooling: 380*141.4*60mm (L*W*H) Water cooling: 380*141.4*72mm (L*W*H)
- PACKING
- 4.5Kg;4pcs/19Kg/2.46CUFT
Certifications & ratings
- Forced-air cooling
- 380*141.4*60mm
- Water cooling
- 380*141.4*72mm
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance :includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve and Static characteristics for more details.
- 5. Without water or fan cooling to provide adequate heat dissipation, OTP might be triggered if trimming output voltage by PV signal toward upper or bottom limits of nominal voltage. Under such condition, enhanced cooling on PSU is highly recommended.
- 6. PV/PC function when users are not operating on PMBus. SVR functions when users are neither operation on PMBus nor using PV/PC.
- 7. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.
- 8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. The efficiency is measured at 75% load.
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
Downloads
Certificates9
Test reports1
Catalogues1
FAQ
Can I use the PHP-3500-24 for a high-current 24V industrial DC bus?
Yes, this model is built for very large 24V constant-voltage loads. It is rated at 3480W with 24V output and 145A output current, which fits heavy industrial power distribution, automation, or test systems designed around a 24V bus.
Is the PHP-3500-24 appropriate for factory test racks or burn-in systems that need programmable 24V output?
It can be a strong fit for that use case because the output voltage and constant current level are programmable. With 3480W at 24V and 145A, it is sized for high-load industrial validation or production equipment rather than light-duty control panels.
Can the PHP-3500-24 support large automation systems that need more than one high-power 24V supply?
Yes, the series supports active current sharing up to 14000W in a 3+1 arrangement. That makes this 3480W, 24V, 145A model relevant when a larger 24V power architecture has to be expanded beyond a single supply.
Is the PHP-3500-24 suitable where fan noise or airflow limits are a concern?
Yes, the unit has no built-in fan: it is a fanless design cooled by conduction through its baseplate, mounted on an aluminum plate or a water cold plate (external fans are an optional alternative). The low-profile 60 mm height (72 mm with the water-cooling plate) can also help in dense industrial equipment layouts.
Can the PHP-3500-24 be used outdoors or in demanding temperature conditions?
The working temperature range is -30°C to +70°C measured at the baseplate, with load derating at higher temperatures according to the derating curve, so it can cover wide temperature conditions. However, no IP rating is listed in the supplied specs, so outdoor exposure should not be assumed without a protective enclosure.
How does the PHP-3500-24 compare with the other PHP-3500 models?
The PHP-3500 series has two output voltages: this PHP-3500-24 at 3480W 24V 145A (95% typical efficiency) and the PHP-3500-48 at 3504W 48V 73A (96% typical efficiency). Each comes as a standard PMBus version or a CAN-suffix CANBus version, and an optional cold plate (ordering no. PGG1WHS-656) is available for water cooling.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other PHP-3500 Models
4 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well PHP-3500-380 Power Supply 3500W 380V 10.5A | 3500W | 380V | 10.5A | View |
| Mean Well PHP-3500-230 Power Supply 3500W 230V 16.1A | 3500W | 230V | 16.1A | View |
| Mean Well PHP-3500-115 Power Supply 3500W 115V 26.3A | 3500W | 115V | 26.3A | View |
| Mean Well PHP-3500-48 power supply 3500W 48V 73A | 3504W | 48V | 73A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.