Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLC-100-12 is the 12V output model of this series: rated current 5A, rated power 60W, typical efficiency 83%.
Features
- Universal AC input / Full range
- High efficiency up to 88.5%
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- Built-in active PFC function
- Class 2 power unit
- Pass LPS
- 100% full load burn-in test
- High reliability
- Suitable for LED lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CONSTANT CURRENT REGIONNote.4
- 9 ~ 12V
- RATED CURRENTNote.6
- 5A
- CURRENT RANGENote.6
- 0 ~ 5A
- RATED POWERNote.6
- 60W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE(Vo ADJ)
- 10.2 ~ 12V
- CURRENT ADJ. RANGE(Io ADJ)
- 3.75 ~ 5A
- VOLTAGE TOLERANCENote.3
- ±3.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIME
- 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 60ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧75% at 115VAC/230VAC input
- EFFICIENCY (Typ.)
- 83%
- AC CURRENT (Typ.)
- 12V:0.8A/115VAC 0.4A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 40A(twidth=950μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENT (Typ.)Note.4
- 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13 ~ 16V Protection type : Shut down and latch off o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL1310, TUV BS EN/EN60950-1, BS EN/EN61347-1, BS EN/EN61347-2-13, GB/T19510.1,GB/T19510.213, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, GB/T 17743, GB17625.1, BS EN/EN61000-3-2,-3, Class C (≧70% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55035, light industry level, (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 2688.3K hrs min. Telcordia SR-332 (Bellcore) ; 297.9Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 200.5*69.5*35mm (L*W*H)
- PACKING
- 0.52Kg; 25pcs/14Kg/0.65CUFT
Certifications & ratings
- Marked features
- LPS, PFC
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.
- 7. Safety and EMC design refer to BS EN/EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. PLC-100-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).
Technical drawings
Downloads
Datasheet1
Certificates6
Catalogues1
FAQ
What kinds of applications is the Mean Well PLC-100-12 designed for?
This model is intended for LED lighting and moving sign applications. It provides a 12V output and includes constant current limiting behavior, which makes it relevant for commercial and industrial low-voltage lighting use cases.
Is the PLC-100-12 a 12V power supply?
Yes. The provided product data lists this model with a 12V output voltage and a rated current of 5A. That makes it a fit for equipment designed to operate from a 12V DC power source.
Does the PLC-100-12 support dimming control?
No dimming control is listed for this model. The product data specifically shows dimming control as none, so it should not be selected when built-in dimming functionality is required.
What protection features are included on the PLC-100-12?
The datasheet lists over current protection (constant current limiting), over voltage protection and over temperature protection. These built-in protections help support reliability in demanding LED power applications.
Can the PLC-100-12 be used in environments with temperature extremes?
The provided operating temperature range is -30°C to 50°C, with load derating at higher temperatures per the derating curve. That gives this model a relatively wide working range for many indoor and protected commercial environments.
What makes the PLC-100-12 different from a basic non-PFC power supply?
This model includes a built-in PFC circuit, with the datasheet stating a typical PF greater than 0.95 at full load. Compared with a basic non-PFC unit, that is a meaningful feature for buyers who prioritize power quality and commercial-grade performance.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other PLC-100 Models
6 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well PLC-100-48 Power Supply 100W 48V - PFC 2A | 96W | 48V | 2A | IP20 | View |
| Mean Well PLC-100-36 Power Supply 100W 36V - PFC 2.65A | 95.4W | 36V | 2.65A | IP20 | View |
| Mean Well PLC-100-27 Power Supply 100W 27V - PFC 3.55A | 95.85W | 27V | 3.55A | IP20 | View |
| Mean Well PLC-100-24 Power Supply 100W 24V - PFC 4A | 96W | 24V | 4A | IP20 | View |
| Mean Well PLC-100-20 Power Supply 100W 20V - PFC 4.8A | 96W | 20V | 4.8A | IP20 | View |
| Mean Well PLC-100-15 Power Supply 100W 15V - PFC 5A | 75W | 15V | 5A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.