Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLC-100-20 is the 20V output model of this series: rated current 4.8A, rated power 96W, typical efficiency 88.5%.
Features
- Universal AC input / Full range
- High efficiency up to 88.5%
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- Built-in active PFC function
- Class 2 power unit
- Pass LPS
- 100% full load burn-in test
- High reliability
- Suitable for LED lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 20V
- CONSTANT CURRENT REGIONNote.4
- 15 ~ 20V
- RATED CURRENTNote.6
- 4.8A
- CURRENT RANGENote.6
- 0 ~ 4.8A
- RATED POWERNote.6
- 96W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE(Vo ADJ)
- 17 ~ 20V
- CURRENT ADJ. RANGE(Io ADJ)
- 3.6 ~ 4.8A
- VOLTAGE TOLERANCENote.3
- ±3.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIME
- 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 60ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧75% at 115VAC/230VAC input
- EFFICIENCY (Typ.)
- 88.5%
- AC CURRENT (Typ.)
- 20V ~ 48V:1.1A/115VAC 0.55A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 40A(twidth=950μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENT (Typ.)Note.4
- 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 22 ~ 27V Protection type : Shut down and latch off o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL1310, TUV BS EN/EN60950-1, BS EN/EN61347-1, BS EN/EN61347-2-13, GB/T19510.1,GB/T19510.213, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, GB/T 17743, GB17625.1, BS EN/EN61000-3-2,-3, Class C (≧70% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55035, light industry level, (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 2688.3K hrs min. Telcordia SR-332 (Bellcore) ; 297.9Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 200.5*69.5*35mm (L*W*H)
- PACKING
- 0.52Kg; 25pcs/14Kg/0.65CUFT
Certifications & ratings
- Marked features
- LPS, PFC
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.
- 7. Safety and EMC design refer to BS EN/EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. PLC-100-12 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).
Technical drawings
Downloads
Datasheet1
Certificates6
Catalogues1
FAQ
What is the Mean Well PLC-100-20 typically used for?
The PLC-100-20 is a 100W class power supply designed for LED lighting and moving sign applications. Its 20V output, built-in active PFC, and constant voltage plus current-limiting design make it a practical fit for commercial and industrial lighting-related systems that need stable DC output.
What are the main output ratings of the PLC-100-20?
This model provides a 20V DC output with a rated current of 4.8A and a power rating of 96W. It also includes adjustable output voltage and current level settings within the product's designed operating range.
Is the PLC-100-20 a constant voltage power supply or a constant current model?
The PLC-100-20 operates in constant voltage mode with a built-in constant current limiting circuit, described as C.V. plus C.C. mode. That means it is primarily a 20V power supply, while also including current-limiting behavior for added protection and control.
Does the PLC-100-20 include power factor correction?
Yes. This model has a built-in PFC circuit with a typical power factor above 0.95 at full load, which is one of its key differentiators for buyers comparing commercial-grade LED power supplies.
What operating temperatures is the PLC-100-20 rated for?
The PLC-100-20 is rated for operation from -30°C to 50°C, with load derating at higher temperatures per the derating curve. That range makes it suitable for a wide variety of indoor and protected-environment applications where temperature stability matters.
What protection and reliability features does the PLC-100-20 include?
This model includes over current (constant current limiting), over voltage and over temperature protection. For reliability, the datasheet lists an MTBF of 2688.3K hours minimum (Telcordia SR-332) and 3.75KVAC input-output withstand voltage.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other PLC-100 Models
6 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well PLC-100-48 Power Supply 100W 48V - PFC 2A | 96W | 48V | 2A | IP20 | View |
| Mean Well PLC-100-36 Power Supply 100W 36V - PFC 2.65A | 95.4W | 36V | 2.65A | IP20 | View |
| Mean Well PLC-100-27 Power Supply 100W 27V - PFC 3.55A | 95.85W | 27V | 3.55A | IP20 | View |
| Mean Well PLC-100-24 Power Supply 100W 24V - PFC 4A | 96W | 24V | 4A | IP20 | View |
| Mean Well PLC-100-15 Power Supply 100W 15V - PFC 5A | 75W | 15V | 5A | IP20 | View |
| Mean Well PLC-100-12 Power Supply 100W 12V - PFC 5A | 60W | 12V | 5A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.