💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well MDS01L-15 DC-DC Converter - 1W - 4.5~5.5V in 15V out 67mA

SKU MDS01L-15
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

MDS01L-15 is the 15V output model of this series: rated power 1W, typical efficiency 75%.

MDS01 and MDD01 series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 83%, wide working temperature range -40~+85℃, 6KVDC or 4.2KVAC I/P-O/P high isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/ 5V/ 12 V/15V for single output and ±5V /±9 V/±12V/±15V for dual outputs, which are suitable for medical systems , ultra low leakage current.

Features

  • SIP7 package with international standard pinout
  • Operating temperature range -40 ~ +85℃
  • Medical safety approved (1xMOPP/2xMOOP) according to ANSI/AAMI ES60601-1
  • Low patient leakage current <2μA
  • Protection: Short circuit(3 second max.)
  • 6KVDC or 4.2KVAC hight I/O isolation (Reinforced isolation)
  • Low cost
  • 3 years warranty

Specifications

MDS01L-15Specifications from the official datasheet (2022-05-24 edition)

INPUT

INPUT VOLTAGE (RANGE)
Normal 5V (4.5 ~ 5.5V)
VOLTAGE RANGE
4.5 ~ 5.5Vdc
INPUT CURRENT (NO LOAD)
45mA
INPUT CURRENT (FULL LOAD)
265mA
SURGE VOLTAGE (100ms max.)
5Vin models : 9Vdc 12Vin models : 18Vdc 24Vin models : 30Vdc
FILTER
Internal capacitor
PROTECTION
Fuse recommended. 500mA Slow-Blow Type for all models

OUTPUT

OUTPUT VOLTAGE
15V
OUTPUT CURRENT
7 ~ 67mA
EFFICIENCY (TYP.)
75%
CAPACITOR LOAD (MAX.)* For each output
470μF
VOLTAGE ACCURACY
±5.0%
RATED POWER
1W
RIPPLE & NOISENote.2
75mVp-p
LINE REGULATIONNote.3
1.2% for 1% input variation
LOAD REGULATIONNote.4
±10%
SWITCHING FREQUENCY (Typ.)
100KHz

PROTECTION

SHORT CIRCUIT
3 second max.

ENVIRONMENT

COOLING
Free-air convection
WORKING TEMP.
-40 ~ +85℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-55 ~ +125℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.02% / ℃ (0 ~ 85℃)
SOLDERING TEMPERATURE
1.5mm from case of 1 ~ 3sec./260℃ max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL60601-1, EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE
I/P-O/P:6KVDC or 4.2KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ISOLATION LEVEL
Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC, 50/60Hz
ISOLATION CAPACITANCE (Typ.)
5pF
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55011(CISPR11)Class B
RadiatedBS EN/EN55011(CISPR11)Class B
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 2, ±8KV contact

OTHERS

MTBF
3500Khrs MIL-HDBK-217F(25℃)
DIMENSION (L*W*H)
19.5*9.8*12.5mm (0.77*0.386*0.492 inch)
CASE MATERIAL
Non-Conductive black plastic (UL 94V-0 rated)
PACKING
4.2g ; 25pcs/per tube, 3000pcs/120 tube/per carton
Test conditions and notes6
  1. 1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 10% to 100% rated load.
  5. 5.Patient leakage current(2μA max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.
  6. 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)

Technical drawings

MDS01L-15 Mechanical Specification
Mechanical Specification
MDS01L-15 EMC Suggestion
EMC Suggestion
MDS01L-15 Packing
Packing

Typical applications

  • Medical devices
  • Medical oxygen monitor
  • CT scanning
  • Medical carts
  • Oral care equipment

Downloads

FAQ

Can I use the MDS01L-15 for a low-power 15V analog or instrumentation rail?

Yes, it is appropriate for small 15V sections in instrumentation, interface, and control electronics where the load stays within 1W. Its output is a fixed, unregulated 15V at up to 67mA, so it is intended for light-duty circuitry rather than larger 15V loads.

Is this a good fit for embedded systems that need a compact 15V auxiliary output?

It can be a good fit when the 15V rail is only supporting a small embedded subcircuit. The package is 19.5 x 9.8 x 12.5 mm, and the rated output is 15V at up to 67mA with a total power limit of 1W.

Can the MDS01L-15 be used inside industrial control hardware for light 15V loads?

Yes, for low-power internal control electronics it matches well. The combination of fixed 15V output, 67mA maximum output current, and 1W rating makes it better for small internal rails than for higher-current automation components.

Does the MDS01L-15 handle cold or hot operating conditions?

The specified operating range is -40 C to +85 C (with load derating at higher temperatures, see the derating curve), which supports use across a broad temperature span. No IP rating is provided in the product data, so enclosure-level protection would determine indoor or outdoor exposure suitability.

What is the difference between the MDS01L-15 and the other MDS01L models?

The MDS01L series includes 1W versions at 3.3V, 5V, 12V, and 15V output. The siblings are MDS01L-03 at 3.3V up to 303mA, MDS01L-05 at 5V up to 200mA, and MDS01L-12 at 12V up to 84mA.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8442607141163, "variants" :[{ "context":"default", "variant_id": 45711597076779, "sku":"MDS01L-15", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well MDS01L-15 DC-DC Converter - 1W - 4.5~5.5V in 15V out 67mA
Mean Well

Mean Well MDS01L-15 DC-DC Converter - 1W - 4.5~5.5V in 15V out 67mA

MDS01L-15 is the 15V output model of this series: rated power 1W, typical efficiency 75%.

MDS01 and MDD01 series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 83%, wide working temperature range -40~+85℃, 6KVDC or 4.2KVAC I/P-O/P high isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/ 5V/ 12 V/15V for single output and ±5V /±9 V/±12V/±15V for dual outputs, which are suitable for medical systems , ultra low leakage current.

Features

  • SIP7 package with international standard pinout
  • Operating temperature range -40 ~ +85℃
  • Medical safety approved (1xMOPP/2xMOOP) according to ANSI/AAMI ES60601-1
  • Low patient leakage current <2μA
  • Protection: Short circuit(3 second max.)
  • 6KVDC or 4.2KVAC hight I/O isolation (Reinforced isolation)
  • Low cost
  • 3 years warranty

Typical applications

  • Medical devices
  • Medical oxygen monitor
  • CT scanning
  • Medical carts
  • Oral care equipment
View product