Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MDS01M-05 is the 5V output model of this series: rated power 1W, typical efficiency 78%.
MDS01 and MDD01 series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 83%, wide working temperature range -40~+85℃, 6KVDC or 4.2KVAC I/P-O/P high isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/ 5V/ 12 V/15V for single output and ±5V /±9 V/±12V/±15V for dual outputs, which are suitable for medical systems , ultra low leakage current.
Features
- SIP7 package with international standard pinout
- Operating temperature range -40 ~ +85℃
- Medical safety approved (1xMOPP/2xMOOP) according to ANSI/AAMI ES60601-1
- Low patient leakage current <2μA
- Protection: Short circuit(3 second max.)
- 6KVDC or 4.2KVAC hight I/O isolation (Reinforced isolation)
- Low cost
- 3 years warranty
Specifications
INPUT
- INPUT VOLTAGE (RANGE)
- Normal 12V (10.8 ~ 13.2V)
- VOLTAGE RANGE
- 10.8 ~ 13.2Vdc
- INPUT CURRENT (NO LOAD)
- 15mA
- INPUT CURRENT (FULL LOAD)
- 105mA
- SURGE VOLTAGE (100ms max.)
- 5Vin models : 9Vdc 12Vin models : 18Vdc 24Vin models : 30Vdc
- FILTER
- Internal capacitor
- PROTECTION
- Fuse recommended. 500mA Slow-Blow Type for all models
OUTPUT
- OUTPUT VOLTAGE
- 5V
- OUTPUT CURRENT
- 20 ~ 200mA
- EFFICIENCY (TYP.)
- 78%
- CAPACITOR LOAD (MAX.)* For each output
- 1000μF
- VOLTAGE ACCURACY
- ±5.0%
- RATED POWER
- 1W
- RIPPLE & NOISENote.2
- 75mVp-p
- LINE REGULATIONNote.3
- 1.2% for 1% input variation
- LOAD REGULATIONNote.4
- ±10%
- SWITCHING FREQUENCY (Typ.)
- 100KHz
PROTECTION
- SHORT CIRCUIT
- 3 second max.
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- 0.02% / ℃ (0 ~ 85℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL60601-1, EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:6KVDC or 4.2KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION LEVEL
- Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC, 50/60Hz
- ISOLATION CAPACITANCE (Typ.)
- 5pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55011(CISPR11) Class B Radiated BS EN/EN55011(CISPR11) Class B - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±8KV contact
OTHERS
- MTBF
- 3500Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 19.5*9.8*12.5mm (0.77*0.386*0.492 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 4.2g ; 25pcs/per tube, 3000pcs/120 tube/per carton
Test conditions and notes6
- 1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Patient leakage current(2μA max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.
- 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Medical devices
- Medical oxygen monitor
- CT scanning
- Medical carts
- Oral care equipment
Downloads
Certificates5
Test reports1
FAQ
Can I use the MDS01M-05 to derive a small 5V rail inside 12V-class industrial electronics?
Yes, it is aimed at low-power 5V conversion in compact electronics with a 12V nominal (10.8~13.2VDC) supply. The converter is rated for 1W with a fixed 5V output, so it fits light embedded, monitoring, or interface circuitry rather than power-hungry 5V devices.
Is the MDS01M-05 suitable for embedded controllers that need a regulated 5V auxiliary supply?
Only if the 5V section tolerates an unregulated rail: the output is ±5.0% accurate with ±10% load regulation, and the load must stay within the 1W limit. Its small 19.5 x 9.8 x 12.5 mm size also makes it practical for compact controller boards and tightly packed assemblies.
Can this converter be used in automation panels for low-power logic or interface sections?
Yes, for low-power internal 5V logic and interface circuits it is a reasonable match. The operating range of -40 C to +85 C (with load derating at higher temperatures, see the derating curve) also supports use in equipment that sees wide cabinet temperature variation.
Is the MDS01M-05 rated for outdoor exposure?
The temperature specification is -40 C to +85 C (with load derating at higher temperatures, see the derating curve), so the thermal range is broad. However, no IP rating is listed, so the product data does not identify it as an outdoor-exposed or water-resistant unit by itself.
How does the MDS01M-05 compare with the rest of the MDS01M series?
The MDS01M siblings are all 1W converters with output options of 5V, 12V, and 15V. The siblings are MDS01M-12 at 12V up to 84mA and MDS01M-15 at 15V up to 67mA, while the MDS01M-05 delivers 5V up to 200mA.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.