Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
IOB-15-15C is the 15V output model of this series: rated current 1A, rated power 15W, typical efficiency 84%.
The IOB-15 series is a compact and reliable AC-DC open frame power module featuring high efficiency and low power consumption. It is particularly well-suited for space-constrained applications with stringent energy efficiency requirements. The product features a compact design and supports universal input voltage range of 85~305Vac. With ultra-low standby power consumption <0.25W, it is energy efficiency and eco-friendly. It also offers an ultra-wide operating temperature range of -40℃ ~+85℃ as well as complete protection functions to ensure safe and reliable operation. These features make the product suitable for applications with strict space constraints, such as industrial automation, power metering, and smart devices.
Features
- Assemble on the main PCB of the system
- 1.75''x0.86''compact size
- 85~305Vac input (277Vac available)
- No load power consumption <0.25W
- -40~85℃ wide operating temperature
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Safety Class Ⅱ
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT
- 1A
- CURRENT RANGE
- 0 ~ 1A
- RATED POWER
- 15W
- RIPPLE & NOISE (max.)Note.2
- 150mV
- INITIAL SET POINT ACCURACY
- ±3% for 3.3Vdc output, ±2% for other output
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2% for 3.3Vdc output, ±1.5% for 5Vdc output, ±1% for other output
- CAPACITOR LOAD (Max.)
- 2000μF
INPUT
- VOLTAGE RANGE
- 85 ~ 305Vac 100 ~ 430Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 0.4A/115Vac 0.25A/230Vac
- INRUSH CURRENT (Typ.)
- 18A/115Vac 35A/230Vac
- NO LOAD POWER CONSUMPTION
- <0.25W
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery, Hiccup mode
- OVERLOAD
- >110% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE (Max.)
- 20Vdc Protection type : Output voltage clamp
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.Note.4
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +105℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.15% / ℃ max. (0 ~ 85℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- LVD IEC62368-1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVac leakage current <5mA
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500Vdc / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32) Class A without external components Radiated BS EN/EN55032(CISPR32) Class B with external components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, ±6KV contact criteria B Radiated Susceptibility BS EN/EN61000-4-3 Level 3, 10m/V contact criteria A EFT/Bursts BS EN/EN61000-4-4 Level 2, ±2KV Surge BS EN/EN61000-4-5 Level 2, ±1KV Line-Line Conducted BS EN/EN61000-4-6 Level 2, 10Vrms Criteria A Voltage Dips and Interruptions BS EN/EN61000-4-11 0%, 70% perf. Criteria B
OTHERS
- MTBF (Typ.)
- >10000Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- A Type : 44.5*25*15mm (1.751*0.984*0.59 inch) ; B Type : 44.5*25.5*15mm (1.751*1.003*0.59 inch) C Type : 44.5*23*15.5mm (1.751*0.905*0.61 inch)
- PACKING
- A,B Type :11.2g ; 49pcs/per Tray, 637pcs/13 Tray/per carton C Type :11.2g ; 56pcs/per Tray, 448pcs/8 Tray/per carton
Test conditions and notes5
- 1.All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 4.When starting at a low temperature of -40℃, the output capacitor needs to be equipped with a solid capacitor to meet the load reduction curve requirements.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Hand-held electronic device
- Smart home
- Industrial control
Downloads
FAQ
What kind of applications is the Mean Well IOB-15-15C designed for?
The IOB-15-15C is an on-board AC-DC power module intended to be assembled directly on the main PCB of a system. It is suited to compact embedded equipment where a small footprint, internal power conversion, and low no-load power consumption are important.
What are the key electrical characteristics of this power module?
This model is rated for 15W output power and accepts a wide 85 to 305Vac input range, with 100 to 430Vdc input also listed. It also features low no-load power consumption of less than 0.25W and ripple and noise specified at 150mV.
Is the IOB-15-15C suitable for harsh temperature environments?
Yes. The specified operating temperature range is -40°C to +85°C, which makes it suitable for equipment that may face cold starts or elevated internal temperatures. Thermal performance should still be evaluated against the product's derating curve in the final application.
What protections are built into the IOB-15-15C?
The module includes short circuit, overload, and over voltage protection. Short circuit and overload protection use hiccup mode with automatic recovery after the fault condition is removed, and over voltage protection is listed as output voltage clamp.
How compact is this module compared with larger enclosed power supplies?
The IOB-15-15C is much smaller than a typical enclosed AC-DC power supply because it is built as a PCB-mount module. Its dimensions are 44.5 x 24 x 15mm, making it a fit for space-constrained designs that need integrated power conversion.
What compliance and reliability details are listed for this model?
This module is listed as Safety Class II and approved to IEC62368-1 for LVD safety. It also carries a 3-year warranty, which supports use in commercial and industrial electronic equipment where long-term reliability matters.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other IOB-15 Models
17 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.