Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SPAN02A-12 is the 12V output model of this series: rated power 2W, typical efficiency 83%.
SPAN02 and DPAN02 series are 2W isolated and regulated module type DC-DC converter with SIP 8 package. It features international standard pins, a high efficiency up to 85%, wide working temperature range -40~+90℃, 1.5KVDC I/P-O/P isolation voltage, compliance to BS EN/EN55032 radiated class A without additional components, overload and continuous-mode short circuit protection, etc. The models account for different input voltage 4.5~9V, 9~18V, 18~36V and 36~75V 2:1 wide input range, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- SIP8 package with industry standard pinout
- 2:1 wide input range
- Operating temperature range -40 ~ +90℃
- No minimum load required
- Comply to BS EN/EN55032 radiated Class A without additional components
- High efficiency up to 85%
- Protections: Short circuit (Continuous) / Overload
- 1.5KVDC I/O isolation
- Remote ON/OFF control
- 3 years warranty
Specifications
INPUT
- INPUT VOLTAGE (RANGE)
- 12V (9 ~ 18V)
- INPUT CURRENT NO LOAD
- 32mA
- INPUT CURRENT FULL LOAD
- 204mA
- VOLTAGE RANGE
- 9~18Vdc ,
- SURGE VOLTAGE (100ms max.)
- 5Vin models : 15Vdc ; 12Vin models : 25Vdc ; 24Vin models : 50Vdc ; 48Vin models : 100Vdc
- FILTER
- Internal capacitor
- PROTECTION
- Fuse recommended. 5Vin models: 1000mA Slow-Blow Type, 12Vin models: 500mA Slow-Blow Type, 24V and 48Vin models: 250mA Slow-Blow Type
- INTERNAL POWER DISSIPATION
- 500mW
OUTPUT
- OUTPUT VOLTAGE
- 12V
- OUTPUT CURRENT
- 0 ~ 167mA
- EFFICIENCY (TYP.)
- 83%
- CAPACITOR LOAD (MAX.)* For each output
- 167μF
- VOLTAGE ACCURACY
- ±1.5%
- RATED POWER
- 2W
- RIPPLE & NOISENote.2
- 75mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- Single output models:±0.5%, Dual output models:±1%
- SWITCHING FREQUENCY (Typ.)
- 100KHz
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- Protection type : Recovers automatically after fault condition is removed
- UNDER VOLTAGE LOCKOUT Start-up voltage
- 5Vin : 4.2Vdc ; 12Vin : 7.3Vdc ; 24Vin : 15.5Vdc ; 48Vin : 31Vdc
- UNDER VOLTAGE LOCKOUT Shutdown voltage
- 5Vin : 3Vdc ; 12Vin : 5.8Vdc ; 24Vin : 12Vdc ; 48Vin : 24Vdc
FUNCTION
- REMOTE CONTROL
- Power ON: R.C. ~ -Vin <0.8Vdc or open circuit; Power OFF: R.C. ~ -Vin >4 ~ 15Vdc
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +100℃ max.
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- 0.03% / ℃ (0 ~ 85℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC ( Note.5)
- SAFETY STANDARDS
- EAC TP TC 020/2011 (EAC TP TC 004 for 48Vin type only) approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 10pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32) N/A Radiated BS EN/EN55032(CISPR32) Class A - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±8KV air, ±4KV contact Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 1, 0.5KV Surge BS EN/EN61000-4-5 Level 1, 0.5KV Line-Line Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.) Magnetic Field BS EN/EN61000-4-8 Level 2, 3A/m
OTHERS
- MTBF
- 2500Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 21.8*9.2*11.1mm (0.86*0.36*0.44 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 2.7g ; 14pcs/per tube, 2058pcs/147 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input(E:5Vdc, A:12Vdc, B:24Vdc, C:48Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/ datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
FAQ
Can I use the SPAN02A-12 to provide 12V power inside a compact industrial control board?
Yes, it is suited to compact control electronics that need a constant 12V output from a 9-18VDC input source. Its 2W rating and 21.8 × 9.2 × 11.1 mm size make it a fit for low-power industrial board-level use where space is limited.
Is the SPAN02A-12 suitable for embedded 12V monitoring or signal-conditioning circuits?
It can be a fit for embedded and monitoring circuits that require a regulated 12V rail and stay within the 2W output rating. The converter provides constant voltage output and accepts 9-18VDC input, which matches low-power control and sensing designs.
Can I use this 12V converter in automation equipment with a low-voltage DC supply?
Yes, if the automation circuit uses 9-18VDC input and needs a constant 12V output within 2W. This makes it appropriate for low-power automation subcircuits rather than higher-power loads.
Is the SPAN02A-12 a good option when panel space and weight are limited?
It is designed for very small spaces, with dimensions of 21.8 × 9.2 × 11.1 mm and a weight of 2.7g. That small package is useful in dense industrial or embedded assemblies where available board area is tight.
How does the SPAN02A-12 compare with other SPAN02A models?
Within the SPAN02A series, all listed models are 2W converters. The siblings are SPAN02A-03 at 3.3V and 500mA, SPAN02A-05 at 5V and 400mA, SPAN02A-12 at 12V and 167mA, and SPAN02A-15 at 15V and 134mA.
Can the SPAN02A-12 be used in harsh temperature environments?
It is rated for operation from -40°C to +90°C, so it covers a wide temperature range for industrial equipment. No IP rating is listed in the provided specs, so outdoor or washdown suitability is not established by this data alone.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SPAN02 Models
15 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.