Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MDS15C-15 is the 15V output model of this series: rated power 15W, typical efficiency 87%.
MDS15 series is 15W isolated and regulated module type medical grade DC-DC converter with 2"x1" package. It features international standard pins, a high efficiency up to 88%, wide working temperature range -40~+90℃, 4KVAC I/P-O/P high isolation voltage, compliance with IEC60601-1 medical standard, continuous-mode short circuit protection, etc. The models account for different input voltage 9~18V, 18~36V and 36~75V 2:1 wide input range, and various output voltage 5V/12V/15V/24V, which are suitable for medical systems, ultra low leakage current.
Features
- DIP 2"x1" package with international standard pinout
- 2:1 wide input range
- Low patient leakage current <5μA
- Wide operating temperature range -40 ~ +90℃
- Medical safety approved (2xMOPP) according to IEC60601-1
- No minimum load required
- Protections: Short circuit (Continuous) / Overload / Input under voltage
- 4000VAC high I/O isolation (Reinforced isolation)
- 3 years warranty
Specifications
MODEL SELECTION TABLE
- INPUT VOLTAGE (RANGE)
- Normal 48V (36 ~ 75V)
- INPUT CURRENT NO LOAD
- 5mA
- INPUT CURRENT FULL LOAD
- 360mA
- OUTPUT VOLTAGE
- 15V
- OUTPUT CURRENT
- 1000mA
- EFFICIENCY (Typ.)
- 87%
- CAPACITOR LOAD (MAX.)
- 720μF
INPUT
- VOLTAGE RANGE
- 36~75Vdc
- SURGE VOLTAGE (100ms max.)
- 12Vin models : 25Vdc, 24Vin models : 50Vdc, 48Vin models : 100Vdc
- FILTER
- Pi type
- PROTECTION
- Fuse recommended. 12Vin models: 4A delay time Type, 24Vin models: 2A delay time Type, 48Vin models: 1A delay time Type
OUTPUT
- VOLTAGE ACCURACY
- ±1%
- RATED POWER
- 15W
- RIPPLE & NOISENote.2
- 60mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- SWITCHING FREQUENCY (Typ.)
- 12Vin/24Vin:250KHz, 48Vin:300KHz
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- 110 ~ 185% rated output power Protection type : Recovers automatically after fault condition is removed
- UNDER VOLTAGE LOCKOUT
- 12Vin: 7.5Vdc, 24Vin: 15Vdc, 48Vin: 33Vdc
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +110℃ max.
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- 0.03% / ℃ (0 ~ 70℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC ( Note.6)
- SAFETY STANDARDS
- IEC60601-1(LVD) 3rd edition, EAC TP TC 020/2011(EAC TP TC 004 for 48Vin type only) approved
- WITHSTAND VOLTAGE
- I/P-O/P 4KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 100pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55011 Class A without external components Radiated BS EN/EN55011 Class A without external components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 1, ±15KV air, ±8KV contact Radiated Susceptibility BS EN/EN61000-4-3 Level 1, 10V/m EFT/Bursts BS EN/EN61000-4-4 Level 1, ±2KV Surge BS EN/EN61000-4-5 Level 1, ±1KV Line-Line, ±2KV Line-GND Conducted BS EN/EN61000-4-6 Level 1, 10Vrms(e.m.f.) Magnetic Field BS EN/EN61000-4-8 Level 2, 10A/m
OTHERS
- MTBF
- 1060Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 50.8*25.4*12mm (2*1*0.47 inch)
- CASE MATERIAL
- UL94V-0 plastic case
- PACKING
- 30g; 18pcs/per tube, 432pcs/24 tube max./carton
Test conditions and notes6
- 1.All parameters are specified at normal input(A:12Vdc, B:24Vdc, C:48Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.2xMOPP base on a working voltage of 250Vac between Primary to Secondary.
- 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Medical devices
- Medical oxygen monitor
- CT scanning
- Medical carts
- Oral care equipment
Downloads
FAQ
Can I use the MDS15C-15 for a 15V rail in industrial test or measurement equipment?
Yes, this model provides a constant 15V output at 1A with 15W total power. That makes it suitable for low-power test, measurement, control, and embedded circuits that need 15V from a 36-75Vdc input source.
Is the MDS15C-15 a fit for embedded analog or interface electronics that require 15V?
It can be a fit where the load needs regulated 15V and stays within the 15W output rating. The 1A output current positions it for lighter analog, interface, and support electronics rather than larger 15V subsystems.
Can this converter be used in higher-voltage automation systems that need a small 15V auxiliary output?
Yes, it is intended for systems operating from a 36-75Vdc input range that need a constant 15V output. That is relevant for automation or industrial platforms that distribute a higher input voltage and require a smaller 15V auxiliary rail internally.
Is the MDS15C-15 suitable for space-constrained control assemblies?
Yes, its dimensions are 50.8 x 25.4 x 12.0 mm and its weight is 0.03 kg. Those specs make it practical for compact control, instrumentation, and embedded assemblies where board or enclosure space is limited.
Can the MDS15C-15 be used in outdoor equipment cabinets?
The converter is specified for operation from -40 C to +90 C (load derating applies at higher ambient temperatures per the derating curve), which supports demanding ambient temperatures. However, because no IP rating is listed, the published specs do not confirm weather or moisture protection for outdoor exposure.
How does the MDS15C-15 compare with its sibling models?
The listed MDS15C converters all share a 15W platform and differ by output rating. The siblings are MDS15C-05 at 5V and 3A, MDS15C-12 at 12V and 1.25A, MDS15C-15 at 15V and 1A, and MDS15C-24 at 24V and 625mA.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MDS15 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.