Mean Well MDS15C-24 DC-DC Converter - 15W - 36~75V in 24V out 625mA

SKU MDS15C-24
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

MDS15C-24 is the 24V output model of this series: rated power 15W, typical efficiency 88%.

MDS15 series is 15W isolated and regulated module type medical grade DC-DC converter with 2"x1" package. It features international standard pins, a high efficiency up to 88%, wide working temperature range -40~+90℃, 4KVAC I/P-O/P high isolation voltage, compliance with IEC60601-1 medical standard, continuous-mode short circuit protection, etc. The models account for different input voltage 9~18V, 18~36V and 36~75V 2:1 wide input range, and various output voltage 5V/12V/15V/24V, which are suitable for medical systems, ultra low leakage current.

Features

  • DIP 2"x1" package with international standard pinout
  • 2:1 wide input range
  • Low patient leakage current <5μA
  • Wide operating temperature range -40 ~ +90℃
  • Medical safety approved (2xMOPP) according to IEC60601-1
  • No minimum load required
  • Protections: Short circuit (Continuous) / Overload / Input under voltage
  • 4000VAC high I/O isolation (Reinforced isolation)
  • 3 years warranty

Specifications

MDS15C-24Specifications from the official datasheet (2024-04-30 edition)

MODEL SELECTION TABLE

INPUT VOLTAGE (RANGE)
Normal 48V (36 ~ 75V)
INPUT CURRENT NO LOAD
5mA
INPUT CURRENT FULL LOAD
360mA
OUTPUT VOLTAGE
24V
OUTPUT CURRENT
625mA
EFFICIENCY (Typ.)
88%
CAPACITOR LOAD (MAX.)
220μF

INPUT

VOLTAGE RANGE
36~75Vdc
SURGE VOLTAGE (100ms max.)
12Vin models : 25Vdc, 24Vin models : 50Vdc, 48Vin models : 100Vdc
FILTER
Pi type
PROTECTION
Fuse recommended. 12Vin models: 4A delay time Type, 24Vin models: 2A delay time Type, 48Vin models: 1A delay time Type

OUTPUT

VOLTAGE ACCURACY
±1%
RATED POWER
15W
RIPPLE & NOISENote.2
60mVp-p
LINE REGULATIONNote.3
±0.5%
LOAD REGULATIONNote.4
±0.5%
SWITCHING FREQUENCY (Typ.)
12Vin/24Vin:250KHz, 48Vin:300KHz

PROTECTION

SHORT CIRCUIT
Protection type : Continuous, automatic recovery
OVERLOAD
110 ~ 185% rated output power Protection type : Recovers automatically after fault condition is removed
UNDER VOLTAGE LOCKOUT
12Vin: 7.5Vdc, 24Vin: 15Vdc, 48Vin: 33Vdc

ENVIRONMENT

COOLING
Free-air convection
WORKING TEMP.
-40 ~ +90℃ (Refer to "Derating Curve")
CASE TEMPERATURE
+110℃ max.
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-55 ~ +125℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.03% / ℃ (0 ~ 70℃)
SOLDERING TEMPERATURE
1.5mm from case of 1 ~ 3sec./260℃ max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC ( Note.6)

SAFETY STANDARDS
IEC60601-1(LVD) 3rd edition, EAC TP TC 020/2011(EAC TP TC 004 for 48Vin type only) approved
WITHSTAND VOLTAGE
I/P-O/P 4KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ISOLATION CAPACITANCE (Typ.)
100pF
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55011Class A without external components
RadiatedBS EN/EN55011Class A without external components
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 1, ±15KV air, ±8KV contact
Radiated SusceptibilityBS EN/EN61000-4-3Level 1, 10V/m
EFT/BurstsBS EN/EN61000-4-4Level 1, ±2KV
SurgeBS EN/EN61000-4-5Level 1, ±1KV Line-Line, ±2KV Line-GND
ConductedBS EN/EN61000-4-6Level 1, 10Vrms(e.m.f.)
Magnetic FieldBS EN/EN61000-4-8Level 2, 10A/m

OTHERS

MTBF
1060Khrs MIL-HDBK-217F(25℃)
DIMENSION (L*W*H)
50.8*25.4*12mm (2*1*0.47 inch)
CASE MATERIAL
UL94V-0 plastic case
PACKING
30g; 18pcs/per tube, 432pcs/24 tube max./carton
Test conditions and notes6
  1. 1.All parameters are specified at normal input(A:12Vdc, B:24Vdc, C:48Vdc), rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 0% to 100% rated load.
  5. 5.2xMOPP base on a working voltage of 250Vac between Primary to Secondary.
  6. 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)

Technical drawings

MDS15C-24 Pin Configuration
Pin Configuration
MDS15C-24 Derating Curve
Derating Curve
MDS15C-24 Packing
Packing

Typical applications

  • Medical devices
  • Medical oxygen monitor
  • CT scanning
  • Medical carts
  • Oral care equipment

Downloads

FAQ

Can I use the MDS15C-24 to power a 24V sensor or relay circuit from a 36-75V DC bus?

Yes, this model is a constant-voltage DC-DC converter with a 24V output and a 15W power rating. Its input range is 36-75V, so it fits systems that need regulated 24V from a higher-voltage DC source. It is best suited to lower-power 24V control, sensing, or relay loads that stay within the 15W rating.

Is the MDS15C-24 suitable for embedded industrial control electronics that need isolated 24V power?

It is sized for compact embedded and industrial electronics that need a 24V constant-voltage output rather than a large bulk power supply. The compact 50.8 × 25.4 × 12.0 mm package and 0.03 kg weight make it easier to use where board or enclosure space is limited. The main sizing limit is its 15W output capacity.

Can this converter be used in automation equipment with a wide DC input range?

Yes, the 36-75V input range is useful in automation or control equipment where the upstream DC bus can vary within that span. The unit provides a fixed 24V output in constant-voltage mode. That makes it a fit for low-power 24V subsystems instead of variable-output applications.

How does the MDS15C-24 compare with the other MDS15C models?

All MDS15C models in this group are rated at 15W. The MDS15C-05 outputs 5V at 3A, the MDS15C-12 outputs 12V at 1.25A, the MDS15C-15 outputs 15V at 1A, and the MDS15C-24 outputs 24V at 625mA. The selection difference here is the output voltage and rated output current, not the series power class.

Is the MDS15C-24 appropriate for outdoor or harsh-temperature use?

Its operating temperature range is -40°C to +90°C (load derating applies at higher ambient temperatures per the derating curve), so the temperature spec is broad for demanding environments. However, no IP rating is listed in the provided specs, so it should be treated as a converter for protected indoor housings or enclosed equipment rather than exposed outdoor use. Temperature capability and ingress protection are separate considerations.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8442612875563, "variants" :[{ "context":"default", "variant_id": 45711620931883, "sku":"MDS15C-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well MDS15C-24 DC-DC Converter - 15W - 36~75V in 24V out 625mA
Mean Well

Mean Well MDS15C-24 DC-DC Converter - 15W - 36~75V in 24V out 625mA

MDS15C-24 is the 24V output model of this series: rated power 15W, typical efficiency 88%.

MDS15 series is 15W isolated and regulated module type medical grade DC-DC converter with 2"x1" package. It features international standard pins, a high efficiency up to 88%, wide working temperature range -40~+90℃, 4KVAC I/P-O/P high isolation voltage, compliance with IEC60601-1 medical standard, continuous-mode short circuit protection, etc. The models account for different input voltage 9~18V, 18~36V and 36~75V 2:1 wide input range, and various output voltage 5V/12V/15V/24V, which are suitable for medical systems, ultra low leakage current.

Features

  • DIP 2"x1" package with international standard pinout
  • 2:1 wide input range
  • Low patient leakage current <5μA
  • Wide operating temperature range -40 ~ +90℃
  • Medical safety approved (2xMOPP) according to IEC60601-1
  • No minimum load required
  • Protections: Short circuit (Continuous) / Overload / Input under voltage
  • 4000VAC high I/O isolation (Reinforced isolation)
  • 3 years warranty

Typical applications

  • Medical devices
  • Medical oxygen monitor
  • CT scanning
  • Medical carts
  • Oral care equipment