SGAS15A09-P1J is the 9V output model of this series: rated current 1.66A, rated power 15W, typical efficiency 84%.
SGAS15A is a 15W compact size highly reliable, desktop style single-output green adaptor series, which is compact and convient for carry. This product is a classⅠ power unit (with FG) equipped with the standard IEC320-C14 AC inlet and accepting the input range from 90VAC to 264VAC. The whole series provides different models with output voltages ranging between 5VDC and 24VDC that it can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 86% and the extremely low no-load power consumption below 0.075W, SGAS15A is compliant with USA EISA 2007/DoE, EU ErP, and meet Code of Conduct(CoC) Version 5. The superme feature allows the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire series is approved for international safety regulations; moreover, it adopts the 94V-0 flame retardant plastic case that it can effectively prevent users from electric hazards.
Features
- Extreme small
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14,ClassⅠpower unit
- No load power consumption<0.075W
- Energy efficiency LevelⅥ
- Comply with EISA 2007/DoE,EU ErP and meet CoC Version 5
- Protections: Short circuit / Overload / Over voltage
- Fully enclosed plastic case
- Pass LPS
- ‧7.5V / 18V / 48V models available (by request)
- Various DC plug quick adapter accessory available
- 3 years warranty
Specifications
OUTPUT
- SAFETY MODEL NO.
- SGAS15A09
- DC VOLTAGENote.2
- 9V
- RATED CURRENT
- 1.66A
- CURRENT RANGE
- 0 ~1.66A
- RATED POWER
- 15W
- RIPPLE & NOISE (max.)Note.3
- 80mVp-p
- VOLTAGE TOLERANCENote.4
- ±5.0%
- LINE REGULATIONNote.5
- ±0.5%
- LOAD REGULATIONNote.6
- ±5.0%
- SETUP, RISE, HOLD UP TIME
- 3000ms, 50ms, 10ms at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT
- 0.4A / 100VAC
- INRUSH CURRENT (max.)
- Cold start 30A/ 115VAC 50A / 230VAC
- LEAKAGE CURRENT(max.)
- 0.25mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- >120% rated output voltage Protection type : Clamp by zener diode
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CSA C22.2 NO. 62368-1, TUV BS EN/EN62368-1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC , I/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55032(CISPR32)FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) Class B Radiated emission BS EN/EN55032(CISPR32)FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) Class B Harmonic current BS EN/EN61000-3-2 Class A Voltage flicker BS EN/EN61000-3-3 ------- - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact RF field susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT bursts BS EN/EN61000-4-4 Level 2, 1KV Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/L-N 2KV/L,N-PE Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V Magnetic field immunity BS EN/EN61000-4-8 Level 1, 1A/m Voltage dips , interruption BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- LIFE
- 3 years : 100% load 40℃, 12hours / day
- MTBF
- 507Khrs min. MIL-HDBK-217F(25℃)
- DIMENSION
- 85.7*50.9*33.8mm (L*W*H)
- PACKING
- 150g ; 90pcs / 14Kg / CARTON
CONNECTOR
- PLUG
- See page 4~5 ; Other type available by customer requested
- CABLE
- See page 4~5 ; Other type available by customer requested
Test conditions and notes7
- 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
- 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 4.Tolerance: includes set up tolerance, line regulation, load regulation.
- 5.Line regulation is measured from low line to high line at rated load.
- 6.Load regulation is measured from 0% to 100% rated load.
- 7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
Downloads
Certificates6
Test reports1
FAQ
Can I use the SGAS15A09-P1J with a 9V embedded device or control module?
Yes, if the equipment is designed for 9V and draws no more than 1.66A. This unit is rated for 15W total output, which makes it suitable for lower-power 9V electronics within that range.
Is this 9V power supply a good fit for small lab or test instruments?
It can be used with compact 9V instruments or bench devices that stay within 1.66A and 15W. The wide 90-264VAC input is also useful where AC mains conditions vary between sites.
Can this model power a 9V automation accessory or industrial interface board?
It is intended for 9V output applications and can support accessories or interface boards that do not exceed 1.66A. For low-power automation hardware, the 15W rating defines the upper load limit.
What should I check before pairing this supply with a 9V device?
Check that the device requires 9V and that its demand stays within 1.66A and 15W. Matching the output voltage and staying under both current and power limits is the basic sizing requirement for this model.
Can the SGAS15A09-P1J be used in hot or cold operating areas?
The specified operating temperature range is -20°C to +70°C. The provided specs do not include an IP rating, so temperature capability is listed, but indoor or outdoor exposure should be evaluated separately.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other Related Models
49 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.