Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLN-80H-36B is the 36V output model of this series: rated current 2.3A, rated power 82.8W, typical efficiency 91%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- Fully isolated plastic case with IP64 level
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting, Industrial Lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp locations or outdoor application
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- CONSTANT CURRENT REGIONNote.4
- 21.6 ~ 36V
- RATED CURRENT
- 2.3A
- RATED POWER
- 82.8W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.6
- 33 ~ 40V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer A type only
- CURRENT ADJ. RANGE
- 1.38 ~ 2.3A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.8
- 1200ms,80ms/115VAC 500ms,80ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 91%
- AC CURRENT (Typ.)
- 0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 70A(twidth=485μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 41 ~ 49V
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL8750, CSA C22.2 No. 250.0-08, BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent ; IP64, EAC TP TC 004 approved ; Design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load, 12V model ≧65% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020
OTHERS
- MTBF
- 2786.8K hrs min. Telcordia SR-332(Bellcore) ; 316.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 181*61.5*35mm (L*W*H)
- PACKING
- 0.5Kg; 24pcs/13Kg/0.87CUFT
Certifications & ratings
- Marked features
- 110
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type only.
- 7. Safety and EMC design refer to EN60598-1, CNS15233, FCC part18.
- 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
- 13. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Downloads
Certificates5
Test reports1
Catalogues1
FAQ
Can the HLN-80H-36B power 36V sign lighting modules?
Yes, it is suitable for signage applications and supplies constant current at 2.3A with a 36V output. The LED load should fall within the 21.6-36V CC range and remain at or below 82.8W.
Is this model suitable for 36V retail, display, or perimeter lighting?
It can be, if the lighting system uses a 36V constant-current LED engine that requires 2.3A. The available power is 82.8W, so the full fixture load needs to stay within that rating.
Can I use this with a 36V constant-current LED strip system?
It can work with a 36V constant-current strip or module system that operates from 21.6V to 36V and draws 2.3A. It is not intended for loads outside that current and voltage window.
How much LED strip can the HLN-80H-36B run?
The driver is rated for 82.8W, so divide 82.8W by your strip's watts per meter to estimate the maximum theoretical length. The math is 82.8 ÷ strip W/m = max meters; check your strip rated power per meter and make sure it is a 36V load.
What are the main output differences across the HLN-80H family?
The sibling list includes 12V 60W 5A, 15V 75W 5A, 20V 80W 4A, 24V 81.6W 3.4A, 30V 81W 2.7A, 36V 82.8W 2.3A, 42V 81.9W 1.95A, 48V 81.6W 1.7A, and 54V 81W 1.5A versions. Each output is shown in both A and B variants.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLN-80H Models
16 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.